RTUPS-BPE48V75ART2U External battery module significantly extends runtime when used with a compatible CyberPower UPS. With rugged, industrial-grade metal construction, it can be installed even in demanding environments.
Key Benefits
- Flexible Installation
- Sealed Lead-acid Batteries
- Robust Enclosure
- Fast Battery Charging Design
Typical Applications
- Back Office
- Server Room
- Data Center
Features
- Rack/ Tower Convertible Configurations
- Sealed Lead-acid Batteries
- Built-in charger for External Battery Module(EBM)
- Metal Housing
General
Phase |
Single Phase |
UPS Topology |
Online Double Conversion |
Energy Saving Technology |
Online ECO Mode Efficiency > 96% |
Active PFC Compatibility |
Yes |
Parallel Expansion (Max. Units) |
4 |
Input
Generator Compatibility |
Yes |
Nominal Input Voltage (Vac) |
230 |
Input Voltage Range (Vac) |
110 ~ 276 |
Adjustable Voltage Range (Vac) |
0~80% Load for 110 ~ 276 Vac
0~100% Load for 176 ~ 276 Vac |
Input Frequency (Hz) |
50 ± 5
60 ± 6 |
Input Frequency Detection |
Auto-sensing |
Rated Input Current (A) |
45.5 |
Input Power Factor |
0.99 |
Input Connector Type |
Hardwire Terminal Block |
Output
Capacity (VA) |
10000 |
Capacity (Watts) |
9000 |
On Battery Waveform |
Pure Sine Wave |
On Battery Voltage(s) (Vac) |
208 ± 1%
220 ± 1%
230 ± 1%
240 ± 1% |
Output Voltage Setting |
Configurable |
On Battery Frequency (Hz) |
50 ± 0.1%
60 ± 0.1% |
Output Frequency Setting |
Configurable |
Power Factor |
0.9 |
ECO Mode Voltage Tolerance |
± 10 % |
Overload Protection |
Internal Current Limiting , Circuit Breaker , Fuse |
Overload Protection (Line Mode) |
105~125% Load for 10 min, 125~150% Load for 1 min, 150~170% Load for 10 sec, >170% Load for 1 sec |
Overload Protection (Battery Mode) |
105~125% Load for 2 min, 125~150% Load for 30 sec, >150% Load for 1 sec |
Overload Protection (Bypass Mode) |
125~150% Load for 1 min, 150~170% Load for 10 sec, >170% Load for 1 sec |
Crest Factor |
3 : 1 |
Harmonic Distortion (Linear Load) |
THD<2% |
Harmonic Distortion (Non-linear Load) |
THD<5% |
Internal Bypass |
Automatic Bypass |
Manual Bypass |
Yes |
Outlet(s) – Total |
1 |
Outlet Type |
Hardwire Terminal Block x 1 |
Typical Transfer Time (ms) |
0 |
Battery
Runtime at Half Load (min) |
11 |
Runtime at Full Load (min) |
4 |
Typical Recharge Time (Hours) |
7 |
Maximum Charging Current (A) |
4 |
Start On Battery |
Yes |
Smart Battery Management (SBM) |
Yes |
User-replaceable |
No |
Battery Type |
Sealed Lead-acid |
Single Battery Capacity (AH) |
12 V 9 AH |
Extended Battery Module (EBM) |
BPSE240V75ART3UOA |
Max. EBM Quantity (pcs) |
15 |
Surge Protection & Filtering
Surge Suppression (Joules) |
445 |
EMI/RFI Filtration |
Yes |
Management & Communications
LCD Panel |
Yes |
LCD Information Display |
Operation Type , Power Status , Battery Status , Load Status , Fault & Warning , Other Information , Event & Log |
LCD Setting & Control |
Mode Setting , Alarm Setting , Input & Output , Battery Setting |
LED Indicators |
Line Mode , Battery Mode , Bypass Mode , UPS Fault |
HID Compliant USB Port(s) |
1 |
Serial Port |
RS232 |
Dry Contact (with Relay) |
Optional |
Emergency Power Off (EPO) Port |
Yes |
Audible Alarms |
Battery Mode , Low Battery , Overload , Overcharge , Overheat , UPS Fault |
Management Cable (pcs) |
USB Cable x1 |
Power Management Software |
PowerPanel® Business Edition |
SNMP / HTTP Remote Monitoring |
Yes – with optional RMCARD205 |
Physical
Form Factor |
Rack/Tower |
Enclosure Construction |
Metal |
Color |
Black |
Rackmount Rail |
Yes |
Rackmount Ears |
Yes |
Physical Size – Power Module
Dimensions (WxHxD) (in.) |
17.24 x 5.14 x 26.77 |
Dimensions (WxHxD) (mm.) |
438 x 130.5 x 680 |
Weight (lbs.) |
44.1 |
Weight (kg.) |
20 |
Installed Rack Height (U) |
3 |
Physical Size – Battery Module
Dimensions (WxHxD) (in.) |
17.24 x 5.14 x 26.77 |
Dimensions (WxHxD) (mm.) |
438 x 130.5 x 680 |
Weight (lbs.) |
145.5 |
Weight (kg.) |
66 |
Installed Rack Height (U) |
3 |
Shipping Dimensions
Dimensions (WxHxD) (in.) |
22.6 x 28.7 x 35 |
Dimensions (WxHxD) (mm.) |
575 x 730 x 890 |
Weight (lbs.) |
260.7 |
Weight (kg.) |
118.24 |
Environmental
Operating Temperature (°F) |
32 ~ 104 |
Operating Temperature (°C) |
0 ~ 40 |
Operating Relative Humidity (Non-condensing) (%) |
0 ~ 90 |
Operating Elevation (feet/meters) |
≤1000, Load Derated 1% per 100m from 1000m and 2000m |
Storage Temperature (°F) |
5 ~ 113 |
Storage Temperature (°C) |
-15 ~ 45 |
Storage Relative Humidity (Non-condensing) (%) |
0 ~ 95 |
Storage Elevation (feet/meters) |
0-50,000 feet (0-15,000 meters) |
Online Thermal Dissipation (BTU/hr) |
2672 |
Audible Noise at 1.5M from Surface of Unit (dBA) |
60 |
Certifications
Certifications |
CE |
RoHS |
Yes |
Warranty
Product Warranty Period (Year) |
2 |
Battery Warranty Period (Year) |
2 |